1 kVA / 900 Watt Power Conditioner (200/208/220/230/240 VAC), Voltage Regulator, & Battery Backup UPS

1 kVA / 900 Watt Power Conditioner (200/208/220/230/240 VAC), Voltage Regulator, & Battery Backup UPS

4 Tier Power Protection System – Surge Protection, Real Time Power Conditioning With Voltage Regulation, Pure Sine Wave Output, & Always On Double Conversion Backup Power Technology (Phase Locked To Utility Power Allowing Seamless Transition To Backup Power).

Description

Multiple Backup Time Options:

Model Number: Description (Under Battery Options Drop Down): Approximate Backup Time At Full Load:
BBP-AR-1000-PSW-ONL-230V UPS With Internal Batteries Only (2 Batteries, 12 Volts, 9 Amp Hours Each) 0.22 KWH 11 Minutes
BBP-AR-1000-PSW-ONL-230V-WEBP UPS Plus 1 Extra External Battery Pack (10 Batteries, 12 Volts, 9 Amp Hours Each) 1.08 KWH 58 Minutes
BBP-AR-1000-PSW-ONL-230V-W2EBP UPS Plus 2 Extra External Battery Packs (18 Batteries, 12 Volts, 9 Amp Hours Each) 1.94 KWH 1 Hour 44 Minutes
BBP-AR-1000-PSW-ONL-230V-W3EBP UPS Plus 3 Extra External Battery Packs (26 Batteries, 12 Volts, 9 Amp Hours Each) 2.81 KWH 2 Hours 32 Minutes
BBP-AR-1000-PSW-ONL-230V-W4EBP UPS Plus 4 Extra External Battery Packs (34 Batteries, 12 Volts, 9 Amp Hours Each) 3.67 KWH 3 Hours 19 Minutes
BBP-AR-1000-PSW-ONL-230V-W5EBP UPS Plus 5 Extra External Battery Packs (42 Batteries, 12 Volts, 9 Amp Hours Each) 4.54 KWH 4 Hours 6 Minutes
  • 1000 VA (1 kVA) / 900 Watt (0.9 kW)
  • 110/150/180~300 Volt AC Input / 200/208/220/230/240 Volt AC Output
  • Energy Efficient/High Efficiency UPS Mode >96.5% Efficiency When Enabled
  • LCD Status Measurements Include Voltage, Frequency, Load Level, Battery Level, Output Current, and Estimated Remaining Backup Time
  • Tower
  • Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics
  • Online (Double Conversion) – Highest Level Of Protection Available – Battery Power Always Engaged, No Switching Delay (Phase Locked To Input Power Source)
  • Wide Frequency Input Range (44-66 Hz Auto Sensing) Allows For Generator Power To Be Used As A Primary Or Secondary Input Power Source (Using Automatic Transfer Switch Before UPS)
  • Constant Voltage Regulation (±1%)
  • Constant Frequency Regulation (±1 or ±3% Selectable)
  • Factory Warranty: 3 Years On Electronics And 1 Year Warranty On Batteries
  • Optional Extended Warranty: 5 Years On Electronics And 1 Year Warranty On Batteries
  • Digital Signal Processing (DSP) Allows For Greater Reliability Over Older UPS Designs And Superior Electric Noise Filtration
  • >0.99 Input Power Factor / 0.92 Output Power Factor (Line Mode) / 0.965 Output Power Factor (High Efficiency Mode) For Superior Efficiency And Power Savings
  • INPUT: IEC 320-C14
  • OUTPUT: (3) IEC 320-C13
  • Weight: 27.1 lbs.
  • Dimensions (Inches): 6.1 X 10.2 X 15.9 (W x H x D)
  • Operating Temperature: 32°-104° F
  • Operating Humidity: 20%~95%, Non-Condensing
  • Operating Elevation: 3,280 Feet Without De-Rating
  • Cold Start Capable (Shipped With Cold Start Disabled, Will Enable Automatically After Receiving Power For The First Time After Shipping)
  • CE, RoHS, & REACH
  • Includes Software For Windows Monitoring & Configuration

Replacement Batteries:
-Leoch DJW12-9.0 (Lead Acid), Leoch LP12-9.0 (Lead Acid), Betta Batteries 6-HCNFJ-7.2 (Lead Crystal), Or Battery Backup Power BBP-LIFEPO4-HDR-12V-7.2AH (Lithium Iron Phosphate)